I am simulating radiation production of a X ray machine. The simulation consists of electrons with energies corresponding to the tube voltage impinging on targets with the same material and electron incidence angle of the simulated tube. The results show that one of the K lines of tungsten (57 keV) is missing in the simulated X ray spectra. This problem is not ocurring in the previous versions of geant4. I think the problem could be the LoadData() method in G4FluoData, lines 267-282. Thanks in advance, Daniel Bonifacio Institut of Physics - University of Sao Paulo
The problem is reassigned to the developer responsible of this class.
The same problem still persists in version 9.0. Thanks! Daniel
The fix of the bug was not included in 9.0 release. It will be included in the next patch. Alfonso