the physics used are G4RadioActiveDecay and all the hadronic/EM processes. Firstly I input the proton(200MeV) to the Pb, the simulation will stop when the isotope Ho163[0.0] or Tl194[0.0] is generated. Then I just use any of these two isotopes to input, the simulation will also stop. I don't know why. Maybe something wrong with these two isotopes.
Dear Fan, can you have a look? Greetings, Hans-Peter.
The decay schemes of the two isotopes in question are in complete in the database, hence the problem. A modofication to the code has been introduced in v7.0 for all isotope without a valid decay scheme will be treated as stable.