On DEC in ISO mode (debug and optim) tests 11 and 15 give the following or similar: ionIoni: Knock-on electron cross sections . MeanFreePath is computed at tracking time. delta ray energy sampled from differential Xsection. G4NeutronHPNames: Sorry, this material does not come near to any data. G4NeutronHPNames: Please make sure NeutronHPCrossSections points to the directory, the neutron scattering data are located in. G4NeutronHPNames: The material was: A=18, Z=8 In case the data sets are at present not available in the neutron data library, please contact Hans-Peter.Wellisch@cern.ch *** G4Exception: Aborting execution ***
As it did not occure on any other platform and the strstream seems not different on DEC, I am tempted to think that the env variable might not have been set, or the last patch was missed. Can you please double-check? Many greetings, Hans-Peter.
ooops, was fixed in 2.0, I belief.....but do not quote me on this.