Problem 2532 - Position of carbon ion Bragg Peak
Summary: Position of carbon ion Bragg Peak
Status: RESOLVED FIXED
Alias: None
Product: Geant4
Classification: Unclassified
Component: processes/electromagnetic (show other problems)
Version: 11.1
Hardware: All All
: P4 critical
Assignee: Vladimir.Ivantchenko
URL:
Depends on:
Blocks:
 
Reported: 2023-02-28 00:41 CET by Susanna Guatelli
Modified: 2023-09-28 19:26 CEST (History)
1 user (show)

See Also:


Attachments
Plots (91.02 KB, image/png)
2023-02-28 00:41 CET, Susanna Guatelli
Details

Note You need to log in before you can comment on or make changes to this problem.
Description Susanna Guatelli 2023-02-28 00:41:23 CET
Created attachment 808 [details]
Plots

In Geant4 11.1 there seems to be a problem with the parameterisation of the stopping power for carbon ions. In attachment there are the Bragg Peaks. This needs to be investigated.
Comment 1 Vladimir.Ivantchenko 2023-09-28 19:26:55 CEST
According to validations shown at Geant4 annual workshop: https://indico.cern.ch/event/1307331/contributions/5556532/attachments/2722457/4730267/28G4CM_CortesGiraldo_LightIonBraggPeak.pdf this issue may be closed. Improvements are available in 11.1.p02 and 11.2