Description michel.maire 2022-06-16 16:53:07 CEST
Created attachment 780 [details]
macro

see attachments : macro and printout
Comment 1 michel.maire 2022-06-16 16:54:02 CEST
Created attachment 781 [details]
printout
Comment 2 Vladimir.Ivantchenko 2022-06-19 18:40:34 CEST
Hi Michel,

from my point of view, deactivation of view deactivation of continues or atRest processes is always a problem for Geant4 tracking. There was a proposal to include FatalException for such attempts but we do not yet come to agreement what is the correct reaction on such attempt. I will try to reproduce this situation but will not change anything for the beta release.

Cheers,
Vladimir
Comment 3 michel.maire 2022-06-20 12:06:56 CEST
HI Vladimir,

 In the past, inactivation lead to a crash. So, the message was helpful.
 Now, inactivation seems to work, at least for RadioactiveDecay. The warning is misleading and useless. 
 As it is generated once per event, it can be a heavy noise ... It should be removed.
Comment 4 Vladimir.Ivantchenko 2022-11-04 12:59:32 CET
Hello Michel,

thanks for pointing to the problem. It is fixed and the fix will be publicly available with Geant4 11.1 in December.

Vladimir