Problem 2477 - time threshold for isomers production
Summary: time threshold for isomers production
Status: REOPENED REMIND
Alias: None
Product: Geant4
Classification: Unclassified
Component: processes/hadronic/management (show other problems)
Version: other
Hardware: All All
: P4 minor
Assignee: dennis.herbert.wright
URL:
Depends on:
Blocks:
 
Reported: 2022-03-22 11:57 CET by michel.maire
Modified: 2022-09-25 17:00 CEST (History)
1 user (show)

See Also:


Attachments
printout of /process/had/verbose (3.94 KB, text/plain)
2022-03-22 11:57 CET, michel.maire
Details

Note You need to log in before you can comment on or make changes to this problem.
Description michel.maire 2022-03-22 11:57:04 CET
Created attachment 754 [details]
printout of  /process/had/verbose

The time threshold for isomers production is not the same if RadioactiveDecay process is registered or not.
In Geant4 11.0 : 1 microsecond and 1 nanosecond respectively. 
In attachment, printout of /process/had/verbose with and without RadioactiveDecay registered.
Comment 1 dennis.herbert.wright 2022-09-20 22:50:34 CEST
Default threshold half-life now set to 1 ns in G4Radioactivation.cc
This is now the same as that in G4DeexPrecoParameters.
Comment 2 michel.maire 2022-09-25 17:00:18 CEST
HI Dennis,

 I reopen bugzilla, as the problem remains.

  Cheers,  Michel