Problem 2150 - Set cut in range for protons to zero for HP physics
Summary: Set cut in range for protons to zero for HP physics
Status: RESOLVED FIXED
Alias: None
Product: Geant4
Classification: Unclassified
Component: physics_lists (show other problems)
Version: 10.5
Hardware: All All
: P4 minor
Assignee: Vladimir.Ivantchenko
URL:
Depends on:
Blocks:
 
Reported: 2019-03-17 12:08 CET by Vladimir.Ivantchenko
Modified: 2019-04-08 16:26 CEST (History)
1 user (show)

See Also:


Attachments

Note You need to log in before you can comment on or make changes to this problem.
Description Vladimir.Ivantchenko 2019-03-17 12:08:00 CET
In 10.5 by mistake "cut in range for proton" is 0.7 mm instead of zero (as it was in 10.4) in the Shielding Physics List.

Vladimir

PS. the bug may be assigned to me.
Comment 1 Vladimir.Ivantchenko 2019-03-18 09:45:22 CET
Hi Gunter,

you may assign it to me.

Vladimir
Comment 2 Vladimir.Ivantchenko 2019-04-08 16:25:33 CEST
The problem is fixed for Shilding, QGSP_BIC_HP, QGSP_BIC_AllHP Physics Lists and will be available with the next public release. For other HP Physics Lists the limit was 0.7 mm, it is agreed also set the cut for proton to zero in all HP Phzsics List, this will be not a bug fix but development for the new release.

VI
Comment 3 Vladimir.Ivantchenko 2019-04-08 16:26:13 CEST
It will be included for the patch to 10.5 as well.