Problem 1792 - unrestricted dE/dx for ion
Summary: unrestricted dE/dx for ion
Status: RESOLVED FIXED
Alias: None
Product: Geant4
Classification: Unclassified
Component: processes/electromagnetic (show other problems)
Version: 10.0
Hardware: All All
: P5 trivial
Assignee: Vladimir.Ivantchenko
URL:
Depends on:
Blocks:
 
Reported: 2015-10-05 11:36 CEST by michel.maire
Modified: 2015-10-15 15:34 CEST (History)
0 users

See Also:


Attachments
output (1.36 KB, text/plain)
2015-10-05 11:38 CEST, michel.maire
Details
output fot option 3 (1.57 KB, text/plain)
2015-10-05 11:39 CEST, michel.maire
Details
macro (331 bytes, text/plain)
2015-10-05 11:40 CEST, michel.maire
Details

Note You need to log in before you can comment on or make changes to this problem.
Description michel.maire 2015-10-05 11:36:30 CEST
It seems that G4IonParametrisedLossModel() does not compute correctly unrestricted dE/dx

In attachement a macro for TestEm0, and 2 outputs.
Comment 1 michel.maire 2015-10-05 11:38:16 CEST
Created attachment 360 [details]
output
Comment 2 michel.maire 2015-10-05 11:39:30 CEST
Created attachment 361 [details]
output fot option 3
Comment 3 michel.maire 2015-10-05 11:40:53 CEST
Created attachment 362 [details]
macro
Comment 4 Vladimir.Ivantchenko 2015-10-15 15:34:37 CEST
Hello Michel,

A new tag has been submitted on top of ref-09 with the fix of G4EmCalculator for ions. It is working to me. Please, check if it is OK for you.

Cheers,
Vladimir