Problem 1693 - incident generic ion and G4HadronicProcessStore
Summary: incident generic ion and G4HadronicProcessStore
Status: RESOLVED FIXED
Alias: None
Product: Geant4
Classification: Unclassified
Component: processes/hadronic/management (show other problems)
Version: 10.0
Hardware: All All
: P5 trivial
Assignee: dennis.herbert.wright
URL:
Depends on:
Blocks:
 
Reported: 2014-11-12 13:04 CET by michel.maire
Modified: 2014-11-13 19:43 CET (History)
0 users

See Also:


Attachments
macro + output (1.68 KB, application/octet-stream)
2014-11-12 13:04 CET, michel.maire
Details
macro + output (1.68 KB, text/plain)
2014-11-12 13:20 CET, michel.maire
Details

Note You need to log in before you can comment on or make changes to this problem.
Description michel.maire 2014-11-12 13:04:21 CET
Created attachment 293 [details]
macro + output

In case of incident generic ion, it seems that cross sections are not computed.Macro and result in attachment.
Comment 1 michel.maire 2014-11-12 13:20:48 CET
Created attachment 295 [details]
macro + output
Comment 2 dennis.herbert.wright 2014-11-13 19:43:18 CET
Problem solved by Vladimir Ivantchenko with tag  hadr-man-V10-00-16