I have a problem with the program medical_linac, which I cannot make run. The problem is the size of the phamton like next paragraph: User Environment G4ANALYSIS_USE environment variable not set, NO ANALYSIS UI session starts ... /control/saveHistory /run/verbose 2 /run/initialize userDetector->Construct() start. ERROR - G4Box()::G4Box(): Phantom Dimensions too small ! - 3.66, -3.25, -1.63 *** G4Exception : InvalidSetup issued by : G4Box::G4Box() Invalid dimensions. Too small. *** Fatal Exception *** core dump *** *** G4Exception: Aborting execution *** Abortado
*** Problem 999 has been marked as a duplicate of this problem. ***
(In reply to comment #0) > I have a problem with the program medical_linac, which I cannot > make run. The problem is the size of the phamton > like next paragraph: > > > > User Environment > > G4ANALYSIS_USE environment variable not set, NO ANALYSIS > > UI session starts ... > > /control/saveHistory > > /run/verbose 2 > > /run/initialize > > userDetector->Construct() start. > > ERROR - G4Box()::G4Box(): Phantom > > Dimensions too small ! - 3.66, -3.25, -1.63 > > > > *** G4Exception : InvalidSetup > > issued by : G4Box::G4Box() > > Invalid dimensions. Too small. > > *** Fatal Exception *** core dump *** > > > > *** G4Exception: Aborting execution *** > > Abortado Can you please tell me the minimum voxel dimension do you need and for which you suffer this problem? Pablo Cirrone