Summary: Missing fluorescence peak in Low Energy physics model (G4.8.2.p01)
Product: Geant4 Reporter: daniel
Component: processes/electromagnetic/lowenergyAssignee: alfonso.mantero
Status: RESOLVED INVALID    
Severity: normal CC: pia
Priority: P2    
Version: other   
Hardware: PC   
OS: Linux   

Description daniel 2007-03-15 08:47:54 CET
I am simulating radiation production of a X ray machine. The simulation consists
of electrons with energies corresponding to the tube voltage impinging on
targets with the same material and electron incidence angle of the simulated
tube. The results show that one of the K lines of tungsten (57 keV) is missing
in the simulated X ray spectra. This problem is not ocurring in the previous
versions of geant4. I think the problem could be the LoadData() method in
G4FluoData, lines 267-282.

Thanks in advance,
Daniel Bonifacio
Institut of Physics - University of Sao Paulo
Comment 1 Maria.Grazia.Pia 2007-03-15 09:46:59 CET
The problem is reassigned to the developer responsible of this class.
Comment 2 daniel 2007-07-12 20:29:39 CEST
The same problem still persists in version 9.0.
Thanks!
Daniel
Comment 3 alfonso.mantero 2007-07-16 19:26:16 CEST
The fix of the bug was not included in 9.0 release. 
It will be included in the next patch.

Alfonso