Problem 725

Summary: Surface conditions for CSG
Product: Geant4 Reporter: smitha.thrivikraman
Component: geometry/solidsAssignee: Gabriele Cosmo <Gabriele.Cosmo>
Status: RESOLVED INVALID    
Severity: normal    
Priority: P2    
Version: 7.0   
Hardware: All   
OS: Linux   

Description smitha.thrivikraman 2005-02-21 06:35:36 CET
It is known that BREPS are made up of different surfaces that have different
surface conditions. Is it possible to assign different surface conditions to
different surfaces of a CSG solid?
Comment 1 Gabriele Cosmo 2005-02-22 01:52:59 CET
It's not clear what you mean by "surface conditions", but in general, it is not
advisable to assign different accuracy properties to different surfaces.
Since this is a problem-reporting system, please, do NOT submit questions here,
use the proper Users Forum on Hypernews instead. Thanks.