| Summary: | Large collection factor for proton dE/dX. | ||
|---|---|---|---|
| Product: | Geant4 | Reporter: | aso |
| Component: | processes/electromagnetic/lowenergy | Assignee: | Vladimir.Ivantchenko |
| Status: | RESOLVED LATER | ||
| Severity: | critical | ||
| Priority: | P2 | ||
| Version: | 6.0 | ||
| Hardware: | PC | ||
| OS: | Linux | ||
| URL: | http://202.223.168.11/aso/download/Geant4/G4hLowEnergyIonisationBUG.ppt | ||
|
Description
aso
2004-06-09 22:59:29 CEST
The problem report is reassigned to the Geant4 developer author of G4hLowEnergyIonisation. Best regards, Maria Grazia Pia Problem is exist. The source of it is that ICRU parameterization is availbale below 1 MeV, Bethe-Block formula is accurate above 8-10 MeV. The solution will be to use updated parameterization on which we are working currently. |