Problem 432

Summary: Incorrect myltiply scattering angle
Product: Geant4 Reporter: A.Sokolov
Component: processes/electromagneticAssignee: Laszlo.Urban
Status: RESOLVED FIXED    
Severity: normal    
Priority: P2    
Version: 4.1   
Hardware: PC   
OS: Linux   
URL: http://www-linux.gsi.de/~sokolov/MVD2.ps

Description A.Sokolov 2002-12-04 07:25:55 CET
I have simulated muon beam distribution after passing 1 cm Si target. It is two
times narrowed compares with PDG formula prediction and 1.8 times narrowed
compares with version 4.0 prediction.
Comment 1 Laszlo.Urban 2002-12-05 05:42:59 CET
Thanks for submitting this problem report. The MSC angle distribution