Problem 376

Summary: G4Trap cannot be created with pDX3 or pdX4 = 0
Product: Geant4 Reporter: Pedro.Arce
Component: geometry/solidsAssignee: Vladimir.Grichine
Status: RESOLVED WORKSFORME    
Severity: normal    
Priority: P2    
Version: 4.0   
Hardware: All   
OS: All   

Description Pedro.Arce 2002-06-04 07:54:52 CEST
We have these new volumes in the electromagnetic calorimeter of CMS and we need
to build them.
Comment 1 Vladimir.Grichine 2002-06-11 08:47:59 CEST
Practically both fDx3 and fDx4 can be small enough, let say 1000*kCarTolerance,
which is 0.001 micron and very far from mechanical accuracy. If one nevertheless
will try to put exactly zero, G4Trap will loose its topology transforming to a