Problem 2592

Summary: radioactivedecay biasing
Product: Geant4 Reporter: michel.maire
Component: processes/hadronic/models/radioactive_decayAssignee: Vladimir.Ivantchenko
Status: ASSIGNED ---    
Severity: minor CC: Alberto.Ribon, alexander.howard, dennis.herbert.wright, laurent.desorgher, michel.maire, Vladimir.Ivantchenko
Priority: P4    
Version: 11.2   
Hardware: All   
OS: All   

Description michel.maire 2024-02-05 14:27:41 CET
after merge request 4186 (eg. radioactive_decay-V11-02-00) the macro rdecay01/TimeWindowBiased.mac is not working well. The final ion is not created; histogram 8 is empty.
Comment 1 michel.maire 2024-02-25 19:06:44 CET
HI Dennis and All,

 Please compare printout of 11.0 and 11.2

 Final ion, here Ti47, is not created. Then rdecay01 cannot identify the end of decay chain (lines 137 and 180 of TrackingAction), hence not compute the statistic of the event.
 I suspect the origin of this fact is in radioactive_decay-V11-02-00 (MR 4186).

 Dennis, I remember that, once in the past (when ?), we had this problem (eg. final ion not created) that you were able to restaure !
Comment 2 alexander.howard 2024-03-04 15:44:59 CET
(In reply to michel.maire from comment #0)
> after merge request 4186 (eg. radioactive_decay-V11-02-00) the macro
> rdecay01/TimeWindowBiased.mac is not working well. The final ion is not
> created; histogram 8 is empty.

The problem is not related to MR 4186 - this simply protected creating metastable states with infinite lifetime (i.e. stable) due to the zero energy level transitions which should be handled by the upcoming "floating" implementation. I think the issue with the empty histogram 8 occurred 
directly after the beta release of last year, so some months before the release v11.2.
Comment 3 michel.maire 2024-05-04 15:09:43 CEST
remove the command rdm/BRbias from TimeWindowBiased.mac; the biasing of decay time becomes visible again.
But weight of an event is always 1. See trackingAction, lines 184-185; and histo 8