| Summary: | degraded accuracy of the energy loss fluctuation (G4UniversalFluctuation model) in Geant4-11.0 | ||
|---|---|---|---|
| Product: | Geant4 | Reporter: | Mihaly Novak <mihaly.novak> |
| Component: | processes/electromagnetic/standard | Assignee: | Vladimir.Ivantchenko |
| Status: | RESOLVED FIXED | ||
| Severity: | minor | ||
| Priority: | P4 | ||
| Version: | 11.0 | ||
| Hardware: | All | ||
| OS: | All | ||
| Attachments: |
demonstration of the problem (generated by using TestEm5): energy loss distribution of 100 MeV electrons in 5.6 [um] Silicon target
updated plot including the current master result |
||
|
Description
Mihaly Novak
2022-01-31 15:05:09 CET
Hi Mihaly, can you, please, check the current master? If this test will not improve situation significantly, then we will change configuration for Opt4 EM physics in a way that the old fluctuation model is used. Vladimir Created attachment 751 [details]
updated plot including the current master result
Hi Vladimir,
You can find the plot attached updated now with the results obtained by using the current master (as of 25th February 2022).
Cheers,
Mihaly
Hi, Mihaly, Thanks! So, the improvement is significant but still the 10.7 model is better. So, let us include 10.7 variant of the model into Opt4 EM physics for e+-, mu+-, pi+-, p, pbar. Vladimir |