Problem 2440

Summary: range of alpha
Product: Geant4 Reporter: michel.maire
Component: processes/electromagnetic/standardAssignee: Vladimir.Ivantchenko
Status: RESOLVED FIXED    
Severity: normal    
Priority: P4    
Version: 10.7   
Hardware: All   
OS: All   

Description michel.maire 2021-10-28 04:34:14 CEST
This is continuation of problem 2439
After MR 2251, on 16 October, the range of alpha became wrong in any situations.
example : in water, at 400 MeV, nist/Astar = 77.6 mm  Geant4 = 6.47 mm
Comment 1 Vladimir.Ivantchenko 2021-11-02 11:29:51 CET
Hello Michel,

can you, please, check the master?

Vladimir
Comment 2 Vladimir.Ivantchenko 2021-11-05 11:27:54 CET
This problem is fixed and the fix will be available with the next public release.