Description
Martin Frank
2019-06-25 23:03:49 CEST
Hello Martin, thank you very much for investigation of this problem. I agree that there is factor 2 error in low-energy approximation. The fix will be available with the new Geant4 public version and also may be propagated backward. Cannot say to which versions. If you are using the code now likely optimal will be add factor 0.5 privately. Another problem: the code should be modified for conductors, current version assume low conductivity of media like in Silicon. At this point I do not see an easy solution for today. Vladimir Dear Vladimir, Wow, thank you for your fast response! Yes, we have gone ahead and patched the code with a local factor of 0.5 for now. We will keep an eye out for what versions will be patched and then use them appropriately. Fortunately, we are only interested in the energy deposition in liquid scintillator, so the low conductivity assumption works for us. Thanks again, Martin The fix is already integrated into development version. The problem is fixed. |