| Summary: | Set cut in range for protons to zero for HP physics | ||
|---|---|---|---|
| Product: | Geant4 | Reporter: | Vladimir.Ivantchenko |
| Component: | physics_lists | Assignee: | Vladimir.Ivantchenko |
| Status: | RESOLVED FIXED | ||
| Severity: | minor | CC: | Vladimir.Ivantchenko |
| Priority: | P4 | ||
| Version: | 10.5 | ||
| Hardware: | All | ||
| OS: | All | ||
|
Description
Vladimir.Ivantchenko
2019-03-17 12:08:00 CET
Hi Gunter, you may assign it to me. Vladimir The problem is fixed for Shilding, QGSP_BIC_HP, QGSP_BIC_AllHP Physics Lists and will be available with the next public release. For other HP Physics Lists the limit was 0.7 mm, it is agreed also set the cut for proton to zero in all HP Phzsics List, this will be not a bug fix but development for the new release. VI It will be included for the patch to 10.5 as well. |