Description michel.maire 2018-08-19 14:27:17 CEST
Ag110[117.59 keV] is a metastable state, half life ~250 days.
It is produced by thermal neutron capture on Ag109, cross section ~8 barns.
NeutronHP ignores this channel.

 # Macro file for "Hadr03.cc"
 #
 /run/verbose 2
 #
 /testhadr/det/setIsotopeMat Ag109 47 109 10.49 g/cm3
 #
 /run/initialize
 #
 /process/inactivate hadElastic
 #
 /gun/particle neutron
 /gun/energy 0.0253 eV
 #
 /run/printProgress 1000
 /run/beamOn 10000
Comment 1 michel.maire 2018-08-19 14:33:05 CEST
See hyper news hadronic #1657
Comment 2 Gabriele Cosmo 2018-08-27 08:47:29 CEST

*** This problem has been marked as a duplicate of problem 2079 ***
Comment 3 Gabriele Cosmo 2018-08-29 09:14:50 CEST

*** This problem has been marked as a duplicate of problem 2081 ***