| Summary: | U-234 E0 transition incorrectly emitting gammas | ||
|---|---|---|---|
| Product: | Geant4 | Reporter: | Glen Warren <glen.warren> |
| Component: | processes/hadronic/models/de_excitation/photon_evaporation | Assignee: | Vladimir.Ivantchenko |
| Status: | RESOLVED FIXED | ||
| Severity: | enhancement | CC: | kelsey |
| Priority: | P4 | ||
| Version: | 10.4 | ||
| Hardware: | All | ||
| OS: | All | ||
| URL: | http://hypernews.slac.stanford.edu/HyperNews/geant4/get/hadronprocess/1659.html | ||
|
Description
Glen Warren
2018-08-15 19:29:33 CEST
Hello Glen, thank you for the analysis. Now it seems to be not so simple but we will try to address it in general or for sub-set of levels. VI See also Bugzilla #1986 Hello, Finally, the problem is fixed in PhotonEvaporation5.5, which is delivered with the new Geant4 10.6. This dataset may be used with previous with 10.5 as well. Vladimir |