| Summary: | E0 transitions not being handled correctly | ||
|---|---|---|---|
| Product: | Geant4 | Reporter: | Daniel Cox <danielcox404> |
| Component: | processes/hadronic/models/de_excitation/photon_evaporation | Assignee: | Vladimir.Ivantchenko |
| Status: | ASSIGNED --- | ||
| Severity: | enhancement | CC: | Vladimir.Ivantchenko |
| Priority: | P4 | ||
| Version: | 10.3 | ||
| Hardware: | All | ||
| OS: | All | ||
|
Description
Daniel Cox
2017-06-26 11:29:48 CEST
Hi Dennis, please, switch this problem to me. Hello Daniel, thank you for this bug report. We are in transition to the new code for gamma de-excitation, so it is important to know : which version of G4 you are using, can you reproduce the problem in examples/extended/radioactive_decay/rdecay01. Vladimir Hi Vladimir, I'm running 10.3.1 and can confirm this is still not working in rdecay01. 591 591 0 0+ 0 0.00 0 0 0 0 0 0 0 0 0 0 0 In the, soon to be old, data file z82.a188 this is the line for the first excited 0+ state and it doesn't have any conversion coefficient. Danny Hello Daniel, Absence of conversion for these levels is due to absence this information in our DB. DB is obtained via automatic procedures following by manual corrections. Likely the data are not in ENDF or other sources. The improvement may come from your side if you propose modifications to z82.a188 and z82.a186 files on top of PhotoEvaporation5.2 or PhotoEvaporation4.3. Vladimir |