A primary of 30 Mev is passed directly to pre-compound/de-execitation. Hi Michel, the problem has been fixed and the fix will be available in the next patch. The reason of the problem - in the case of heavy isotopes internal conversion ismay be chosen during sampling but is forbidden by energy, now this situation does not stop the cascade, instead a small energy non-conservation appears. The past solution was used in previous version of de-excitation code. Vladimir |
Created attachment 370 [details] output of Hadr03 in attachment, an output of Hadr03 showing that excited ions are explicitly created in inelastic collisions. The physics is binary cascade (QGSP_BIC_HP).