Problem 1792

Summary: unrestricted dE/dx for ion
Product: Geant4 Reporter: michel.maire
Component: processes/electromagneticAssignee: Vladimir.Ivantchenko
Status: RESOLVED FIXED    
Severity: trivial    
Priority: P5    
Version: 10.0   
Hardware: All   
OS: All   
Attachments: output
output fot option 3
macro

Description michel.maire 2015-10-05 11:36:30 CEST
It seems that G4IonParametrisedLossModel() does not compute correctly unrestricted dE/dx

In attachement a macro for TestEm0, and 2 outputs.
Comment 1 michel.maire 2015-10-05 11:38:16 CEST
Created attachment 360 [details]
output
Comment 2 michel.maire 2015-10-05 11:39:30 CEST
Created attachment 361 [details]
output fot option 3
Comment 3 michel.maire 2015-10-05 11:40:53 CEST
Created attachment 362 [details]
macro
Comment 4 Vladimir.Ivantchenko 2015-10-15 15:34:37 CEST
Hello Michel,

A new tag has been submitted on top of ref-09 with the fix of G4EmCalculator for ions. It is working to me. Please, check if it is OK for you.

Cheers,