| Summary: | incident generic ion and G4HadronicProcessStore | ||
|---|---|---|---|
| Product: | Geant4 | Reporter: | michel.maire |
| Component: | processes/hadronic/management | Assignee: | dennis.herbert.wright |
| Status: | RESOLVED FIXED | ||
| Severity: | trivial | ||
| Priority: | P5 | ||
| Version: | 10.0 | ||
| Hardware: | All | ||
| OS: | All | ||
| Attachments: |
macro + output
macro + output |
||
Created attachment 295 [details]
macro + output
Problem solved by Vladimir Ivantchenko with tag hadr-man-V10-00-16 |
Created attachment 293 [details] macro + output In case of incident generic ion, it seems that cross sections are not computed.Macro and result in attachment.