Summary: step limitation inactivation
Product: Geant4 Reporter: Sebastien Incerti <incerti>
Component: processes/electromagneticAssignee: Vladimir.Ivantchenko
Status: RESOLVED FIXED    
Severity: normal    
Priority: P5    
Version: 10.0   
Hardware: All   
OS: All   

Description Sebastien Incerti 2014-09-05 12:10:25 CEST
Dear Vladimir,

You may want to look at step limitation inactivation when models are set as inactive.

Thanks so much
Sebastien
Comment 1 Vladimir.Ivantchenko 2014-09-22 12:54:45 CEST
Dear Sebastian,

the problem will be studied - it may affect different setups.

VI
Comment 2 Vladimir.Ivantchenko 2014-10-23 09:51:42 CEST
Hello,

The bug has been understood, the fix is committed to the development version and will be available with the next public release.