Description
michel.maire
2014-05-07 14:32:49 CEST
Created attachment 269 [details]
done with macro runs.mac
Hi Michel, this is not a bug: in Otp4 EM physics constructor RangeFactor=0.01, while in Otp3 one - 0.04. If one change from 0.01 t0 0.04 the result become identical. Cheers, Vladimir |